NCM: 85334091
Type: Potentiometer
Barcode: 7898252657867
Replaces: CITROËN: 19201H, 9564463180; DACIA: 7700273699; FIAT: 7076359, 7079246, 71737620, 9944468; FORD: 0269983851, 269983851; LANCIA: 71737620; PEUGEOT: 19201H; RENAULT: 7700273699, 7701204055, 7702217302; VOLVO: 91463158; VW: 0269983851, 026 998 385 1, 489983851; DELPHI: SS10693, SS10693-12B1, SS10692; MTE-THOMSON: 7232; ACI-AVESA: APT-049; BOSCH: F 000 99S 001; DIPASPORT: INJSPF001DLPN, INJSPF001MRLN; EPS: 1.995.001, 1.995.093; ERA: 550149, 550149A, 550224A; FACET: 10.5001, 10.5093; FISPA: 84.102, 84.102A2, 84.144; GAUSS: GS7393; HELLA: 6PX 008 476-461, 6PX 008 476-521, 6PX 008 476-741; HERTH+BUSS ELPARTS: 70650010; HOFFER: 7513001, 7513001E, 7513109; INTERMOTOR: 19926, 19978; KW: 495 001, 495 093; LUCAS: SEB1064, SEB223; MAGNETI MARELLI: 219244240500, 359000603600, 40416002, 404 217 02; MEAT & DORIA: 83001, 83001E, 83109; METZGER: 0904020, 0904021, 0904042; MEYLE: 16-14 813 0001; MOBILETRON: TP-E005, TP-E016; MOTAQUIP: LVTP119, LVTP141; OSSCA: 16288, 16293; QUINTON HAZELL: XPOT348, XPOT411; SIDAT: 84.102, 84.102A2, 84.144; Stark: SKTPS-0380009; TOPRAN: 721 626; VEMO: V22-72-0040, V46-72-0082; WAGNER: THR00001, THR00007; WILMINK GROUP: WG1014944, WG1014974, WG1493358, WG1493442, WG1499451, WG1965042; CALORSTAT by Vernet: TP0021, TP0031; WALKER PRODUCTS: 200-1351; MAXGEAR: 24-0017; ELTA AUTOMOTIVE: EE8003, EE8026; AUTOTEAM: L4102, L4102A2, L4144; PATRON: PE30002, PE30005, PTH054; MDR: EPS-1995 001, EPS-1995 093; BBR Automotive: 027-40-13627; CSV electronic parts: CPM9102, CPM9102C, CPM9144; WE PARTS: 410600002, 410600032, 410600077; NTY: ECP-RE-010; RIDEX: 3940T0009; XEVO: XSP7207, XSP7249; MEC-DIESEL: 900096DP, 900828DP; LEMARK: LTP006, LTP016; ENGITECH: ENT820006; MTR: 12191444; HART: 522 499; A.Z. Meisterteile: AZMT-42-061-1103, AZMT-49-020-2054; RECOFICIAL: CPM9102, CPM9102C, CPM9144; Alfa e-Parts: AF01738
Application: FIAT, FORD, VOLKSWAGEN, RENAULT
BT010 - Order: + - IN
Terminals (Qty): 3
Test Observations: This type of sensor should be tested on the sensors test module with LCD display. To perform the test, follow the procedure:1. Connect the sensors test cables (PU02) to the available inputs below the LCD display and the smaller terminals on the sensor to be tested, as shown in the image2. Adjust the LCD display to show the voltage value: "VOLTS"3. Slowly rotate the sensor mechanism while observing the bar graph and voltage displayed on the LCD display. The voltage should vary between 0V and 4V and the bar should increase continuously